Conduct daily routine checklist to ensure no environmental abnormalities and all critical M&E related systems are in good working condition.
Ensure all subcontractors are inducted and permitted to work within the Critical Environment domain. Review subcontractor method statements, risk assessments, and MSDS to ensure compliance with site health & safety and operating procedures.
Assist the Operation Lead in the daily management of the DC Operations and Periodic Preventive Maintenance Management ensuring 100% uptime of the Dc critical M&E systems.
Conduct daily walkthrough of DC to record and report any faults or defects detected and take down record of M&E equipment.
Ensure that the FOC is monitored and manned at all times and that EPMS, BMS, and Fire System alarms are responded to in a timely manner; contain/isolate the fault identified and provide impromptu escalations/updates base on escalation plan laid.
Comply to site required policies, guidelines and practices.
Briefing and handover to Shift Duty Technician on all outstanding issues and Standing Instructions from the Operation Lead / Assistant Manager / Manager.
Respond to customer service requests in a timely manner.
Maintain a positive and professional working relationship with internal and external clients.
Respond to emergency calls (during shift work).
Maintain log and records of instrument readings, equipment and consumable stock level.
Report all unlocked doors and racks to the security control.
Requirements
electrical diploma
plc
building management
data center
hvac
ms office
Working knowledge of mechanical, electrical, life safety monitoring and control systems typically used in critical environments.
ITE/Nitec/Diploma in Electrical or Mechanical Engineering, Facilities Management, or equivalent field of study required.
Experience of complex automatic control equipment, including relay logic, programmable logic controllers (PLC's), building management systems, and their integration with the data center infrastructure.
Adherence to all quality, health & safety, and environmental policies within the CE domain.
Proficiency in both written and spoken English.
3 to 5 or more years of experience in a data center or other Critical Environment required (preference is given to data center, hospital, pharmaceutical production or power plant experience).
Able to work rotating shifts and on weekends/public holidays.
Advanced knowledge of Microsoft Office Suite - Word, Excel, Outlook and Visio required; working knowledge of SharePoint preferred.
Incidents and field service reporting and filing.
An excellent understanding and experience of the electrical and mechanical systems used in a data center environment, including: Feeders, Transformers, Generators, Fuel Systems, Switchgear, UPS systems, Battery banks, ATS/STS units, PDU/PMM units, Chillers, Air handling units, Chilled water plant, CRAC units, Fire Alarm systems, and Fire Suppression systems.
Proficient knowledge of HVAC and/or Electrical Systems. Team Lead shall be proficient in both Electrical and Mechanical.